Resultado da pesquisa (6)

Termo utilizado na pesquisa Pereira G.G.

#1 - Evaluation of left atrial function in asymptomatic dogs with chronic myxomatous mitral valve disease: twodimensional feature-tracking echocardiography and Simpson’s monoplanar methods

Abstract in English:

The present study evaluated the volume and function of the left atrium by two-dimensional echocardiographic feature-tracking imaging (2D-FTI) and Simpson’s monoplanar modeling in dogs with asymptomatic degenerative mitral valve disease (DMVD). The study consisted of 80 dogs that were divided into the following three groups: Group 1, 21 dogs (A); Group 2, 30 dogs (B1) and Group 3, 29 dogs (B2). The variable strain (contraction phase) was significantly lower in Group 3 than in Group 1 (12.92±4.54 x 16.69±5.74, p=0.014), and significant differences in the contraction strain index (CSI) were observed between all of the groups that were evaluated (1 = 46.82±8.10, 2 = 39.88±8.03, 3 = 35.25±5.64, p<0.0001). The atrial diastolic volume index (AdVi) that was measured by 2D-FTI was significantly higher in Group 3 than in Group 1 (1.31±0.95 x 0.96±0.31, p=0.038), and the atrial cardiac index (ACI) was also higher in Group 3 than in Group 1 (102.38±80.18 x 78.19±33.38, p=0.030). Atrial function was assessed by Simpson’s monoplanar method, which demonstrated an increase in the left atrial systolic volume, while the contractile function decreased with an increasing disease severity (Group 1 0.21±0.06; Group 2 0.25±0.06; Group 3 0.32±0.08, p<0.0001). The intraobserver and interobserver assessments showed low to moderate variability; most of the values for the coefficient of variation for the variables that were analysed with each method were below 25%. Thus, DMVD was determined to cause an alteration in atrial function, especially in the contraction phase, and even in asymptomatic animals, and the methods of 2D-FTI echocardiography and Simpson’s monoplanar evaluation are sensitive and early methods for the detection of left atrial dysfunction.

Abstract in Portuguese:

O presente estudo avaliou o volume e a função atrial esquerda obtidos por meio da ecocardiografia bidimensional feature tracking (2D-FTI) e pelo método monoplanar de Simpson em cães saudáveis e cães com DMVD assintomáticos. Foram avaliados 80 cães distribuídos em três grupos: Grupo 1, 21 cães (classe A); Grupo 2, 30 cães (classe B1) e Grupo 3, 29 cães (classe B2). A variável strain (fase de contração) foi significativamente menor no Grupo 3 que no Grupo 1 (12,92±4,54 x 16,69±5,74, p=0,014) e para a variável índice de strain de contração (CSI), houve diferença estatística entre todos os grupos avaliados (1 = 46,82±8,10; 2 = 39,88±8,03; 3 = 35,25±5,64, p<0,0001). O índice de volume diastólico atrial (iVdA) mensurado por meio do 2D-FTI foi significativamente maior no Grupo 3 que no Grupo 1 (1,31±0,95 x 0,96±0,31, p=0,038), assim como para o índice cardíaco atrial (iCA) também foi maior no Grupo 3 (102,38±80,18 x 78,19±33,38, p=0,030). A função atrial avaliada pelo método monoplanar de Simpson demonstrou um aumento do volume atrial esquerdo e do volume sistólico do átrio esquerdo, enquanto que a função contrátil diminuiu com o aumento da gravidade da doença (Grupo 1 0,21±0,06; Grupo 2 0,25±0,06; Grupo 3 0,32±0,08; p<0,0001). A avaliação intraobservador e interobservador, demonstrou variabilidade baixa a moderada, uma vez que a maioria dos valores de coeficiente de variação se concentraram abaixo de 25% para as variáveis analisadas em ambos os métodos. Dessa forma, conclui-se que a DMVD causa alteração na função atrial, principalmente na fase de contração, mesmo em animais assintomáticos e que a ecocardiografia 2D-FTI e o método monoplanar de Simpson são métodos sensíveis e precoces na detecção da disfunção atrial esquerda.


#2 - Myocardial velocities obtained by pulsed tissue Doppler in English Cocker Spaniels with dilated cardiomyopathy and congestive heart failure, 36(9):851-856

Abstract in English:

ABSTRACT.- Pereira G.G., Goldfeder G.T., Yamaki F.L., Oliveira V.M.C. & Larsson M.H.M.A. 2016. Myocardial velocities obtained by pulsed tissue Doppler in English Cocker Spaniels with dilated cardiomyopathy and congestive heart failure. Pesquisa Veterinária Brasileira 36(9):851-856. Departamento de Clínica Médica, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Prof. Orlando Marques de Paiva 87, São Paulo, SP 05508-900, Brazil. E-mail: ggpereira2002@yahoo.com.br Dilated cardiomyopathy (DCM) is characterized by systolic myocardial dysfunction which is identified by low myocardial velocities obtained by pulsed tissue Doppler (PTD). However, increased preload is known to increase myocardial velocities which could overestimate myocardial function and turn dysfunction characterization into a challenge in dogs with DCM and congestive heart failure. To test the hypothesis that increased preload could hamper identification of low myocardial velocities in dogs with DCM and congestive heart failure the present study prospectively evaluated 32 English Cocker Spaniel dogs, being 16 with clinical DCM and 16 healthy for control purpose. The PTD analysis of regional velocities were performed in both longitudinal and radial myocardial displacements and systolic (Sm), early (Em) and late diastolic (Am) velocities were obtained in left ventricular free wall (LVFW) and interventricular septum (IVS). Peak radial subendocardial and subepicardial Sm velocities were lower in DCM group compared to control (0.065±0.018 vs. 0.102±0.020m/s and 0.059±0.014 vs. 0.094±0.025m/s respectively; p<0.001). Peak longitudinal Sm velocities were lower in basal and medial portions of LVFW (0.093±0.034 vs. 0.155±0.034m/s and 0.091±0.033 vs. 0.134±0.037m/s respectively; p<0.001) and IVS (0.063±0.021 vs. 0.136±0.039 and 0.066±0.026 vs. 0.104±0.032m/s respectively; p<0.001). Most of diastolic velocities were not significantly different between groups, although advanced myocardial disease and dysfunction are expected in DCM group. Reduction in systolic basal and medial longitudinal myocardial velocities and in radial myocardial velocities was the most significant PTD findings. Increased preload did not represent a problem to evaluate systolic dysfunction by PTD in English Cocker Spaniels with DCM, but influence of preload on assessment of diastolic velocities should be better elucidated.

Abstract in Portuguese:

RESUMO.- Pereira G.G., Goldfeder G.T., Yamaki F.L., Oliveira V.M.C. & Larsson M.H.M.A. 2016. Myocardial velocities obtained by pulsed tissue Doppler in English Cocker Spaniels with dilated cardiomyopathy and congestive heart failure. [Velocidades miocárdicas obtidas por meio de Doppler tecidual pulsátil em cães da raça Cocker Spaniel Inglês com cardiomiopatia dilatada e insuficiência cardíaca congestiva.] Pesquisa Veterinária Brasileira 36(9):851-856. Departamento de Clínica Médica, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Prof. Orlando Marques de Paiva 87, São Paulo, SP 05508-900, Brazil. E-mail: ggpereira2002@yahoo.com.br A cardiomiopatia dilatada (CMD) é caracterizada por disfunção miocárdica sistólica, a qual pode ser identificada pelas baixas velocidades miocárdicas obtidas por meio de Doppler tecidual pulsátil (DTP). Contudo, sabe-se que a elevada pré-carga aumenta as velocidades miocárdicas, o que poderia superestimar a função miocárdica e tornar desafiadora a caracterização da disfunção nos cães com CMD e insuficiência cardíaca congestiva. Para testar a hipótese de que a elevada pré-carga pode mascarar a identificação de baixas velocidades miocárdicas nos cães com CMD e insuficiência cardíaca congestiva, o presente estudo avaliou prospectivamente 32 cães da raça Cocker Spaniel Inglês, sendo 16 com manifestações clínicas de CMD e 16 hígidos para efeito de grupo controle. A análise DTP das velocidades regionais foi realizada tanto no deslocamento miocárdico longitudinal quanto radial e foram obtidas as velocidades sistólica (Sm), diastólica inicial (Em) e tardia (Am) na parede livre do ventrículo esquerdo (PLVE) e no septo interventricular (SIV). Os valores de Sm radial subendocárdicos e subepicárdicos foram menores no grupo CMD em comparação com o grupo controle (0,065±0,018 vs. 0,102±0,020m/s e 0,059±0,014 vs. 0,094±0,025m/s, respectivamente; p<0,001). Os valores de Sm longitudinais foram menores nas porções basal e intermediária da parede do ventrículo esquerdo (0,093±0,034 vs. 0,155±0,034m/s e 0,091±0,033 vs. 0,134±0,037m/s, respectivamente; p<0,001) e do septo interventricular (0,063±0,021 vs. 0,136±0,039 e 0,066±0,026 vs. 0,104±0,032m/s, respectivamente; p<0.001). A maioria dos índices diastólicos não apresentou diferença significativa entre os grupos, apesar de a doença miocárdica avançada e a disfunção serem esperadas no grupo CMD. A redução nas velocidades sistólicas longitudinais nos segmentos basais e intermediários e nas velocidades radiais representaram os achados mais relevantes no estudo com DTP. Nos cães da raça Cocker Spaniel Inglês com CMD e insuficiência cardíaca congestiva a pré-carga elevada não representou empecilho para a avaliação da disfunção sistólica por meio de DTP, porém a influência da pré-carga na avaliação das velocidades diastólicas deve ser mais bem investigada.


#3 - Serum dosage of CPK-MB in dogs with ST deviation by chemiluminescence, 34(Supl.1):74-78

Abstract in English:

ABSTRACT.- Santos A.L.F., Pereira G.G., Santos M.M., Gutierrez V.C.R., Calyjur P.C. & Larsson M.H.M.A. 2014. Serum dosage of CPK-MB in dogs with ST deviation by chemiluminescence. Pesquisa Veterinária Brasileira 34(Supl.1):74-78. Setor de Patologia Veterinária, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Orlando Marques de Paiva 87, São Paulo, SP 05508-270, Brazil. E-mail: andrvet@usp.br Although frequently in humans, hypoxic and ischemic heart diseases are poorly documented in dogs, with only few reports of acute myocardial infarction (AMI) in this species. Some electrocardiographic findings might suggest myocardium hypoxia/ischemia, like ST segment elevation or depression, but there are no studies showing whether deviations in ST segment are associated to myocardial injury and serum increase of creatine phosphokinase (CPK-MB). In order to investigate possible myocardial cells injury in poor perfusion conditions, 38 dogs were studied, 20 with normal electrocardiogram and 18 with ST segment elevation or depression, recorded in lead II, at a paper speed of 50 mm/sec and N sensibility (1mV=1cm). Serum measurement of creatine phosphokinase isoenzyme MB (CPK-MB) in normal dogs (group 1) determined control values (in ng/mL), which were compared to those obtained from dogs with deviation (group 2), which allowed confirmation or not of myocardial injury. CPK-MB mean values obtained from dogs in groups 1 and 2 were 0.540ng/ml (SD±0.890)ng/mL and 0.440ng/mL (SD±1.106), respectively. At a significance level of 5%, the relation of CPK-MB with age, mass and total creatine phosphokinase (CPK-T) was not significant in groups 1 and 2. CPK-MB showed no difference, at 5% level, between groups 1 and 2. In conclusion, it is possible to use the human chemiluminescent immunometric assay kit in canine species and that hypoxia/ischemia revealed by ST segment deviation does not mean significant myocardium injury.

Abstract in Portuguese:

RESUMO.- Santos A.L.F., Pereira G.G., Santos M.M., Gutierrez V.C.R., Calyjur P.C. & Larsson M.H.M.A. 2014. Serum dosage of CPK-MB in dogs with ST deviation by chemiluminescence. [A dosagem sérica de CPK-MB em cães com desvio ST por quimiluminescência.] Pesquisa Veterinária Brasileira 34(Supl.1):74-78. Setor de Patologia Veterinária, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Orlando Marques de Paiva 87, São Paulo, SP 05508-270, Brazil. E-mail: andrvet@usp.br Embora frequente em humanos, as doenças hipóxicas e isquêmicas do coração são pouco relatadas em cães, com poucos relatos de infarto agudo do miocárdio (IAM) nesta espécie. Alguns achados no eletrocardiograma podem sugerir hipóxia/isquemia miocárdica, como a elevação ou depressão do segmento ST, mas não há estudos que mostram se os desvios do segmento ST estão associados a lesões miocárdicas e aumento sérico da creatinafosfoquinase (CPK-MB). A fim de investigar possíveis lesões nas células miocárdicas em condições de má perfusão, 38 cães foram estudados, 20 com eletrocardiograma normal e 18 com elevação ou depressão do segmento ST, registrados em papel, na derivação II, velocidade de 50 mm/s e sensibilidade N (1mV = 1cm). A mensuração da creatinafosfoquinase isoenzima MB (CPK-MB) em cães normais (grupo 1) determinou os valores controle (em ng/ml), que foram comparados com os obtidos a partir de cães com desvio (grupo 2), permitindo a confirmação ou não da lesão miocárdica. Os valores médios de CPK-MB obtidos de cães nos grupos 1 e 2 foram 0,540ng/ml (DP±0,890) e 0,440ng / ml (DP ± 1.106), respectivamente. A um nível de significância de 5%, a relação de CPK-MB com a idade, massa e creatinofosfoquinase total (CPK-T) não foi significativa nos grupos 1 e 2. Não houve diferenças na CPK-MB, ao nível de 5%, entre os grupos 1 e 2. Conclui-se que é possível utilizar o kit de ensaio imunométrico por quimioluminescência humano na espécie canina e que a hipoxia/isquemia revelada pelos desvios do segmento ST, não significa lesão miocárdica.


#4 - Assessment of diastolic function by pulsed and color tissue Doppler echocardiography in Maine Coon cats tested for MyBPC-A31P mutation, 34(3):290-300

Abstract in English:

ABSTRACT.- Pellegrino A., Daniel A.G.T., Pereira G.G., Júnior F.F.L., Itikawa P.H. & Larsson M.H.M.A. 2014. [Assessment of diastolic function by pulsed and color tissue Doppler echocardiography in Maine Coon cats tested for MyBPC-A31P mutation.] Avaliação da função diastólica por meio de Doppler tecidual pulsado e colorido em gatos da raça Maine Coon geneticamente testados para a mutação no gene MyBPC-A31P. Pesquisa Veterinária Brasileira 34(3):290-300. Departamento de Clínica Médica, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Prof. Dr. Orlando Marques de Paiva 87, São Paulo, SP, 05508-270, Brazil. E-mail: arinepel@yahoo.com.br Hypertrophic cardiomyopathy (HCM) is the most common feline heart disease and is characterized by increased cardiac mass with a hypertrophied nondilated left ventricle. Myocardial dysfunction occurs in cats with HCM but less is known about dysfunctions in initial stages of HCM. A mutation in MYBPC-A31P gene has been identified in a colony of Maine Coon cats with HCM. However, the close correlation between genotype and phenotype still be inconclusive. Myocardial analysis by tissue Doppler imaging (TDI) is a noninvasive echocardiographic method to assess systolic and diastolic function that is more sensitive than conventional echocardiography. To evaluate diastolic and systolic function in cats with mutation, with or without ventricular hypertrophy, Maine Coon cats (n=57) were screened for mutation and examined with both echocardiography and TDI (pulsed tissue Doppler and color tissue Doppler methods). Then, were phenotypically classified in: normal (n=45), suspects (n=7) and HCM group (n=5); and genotypically classified in: negative (n=28), heterozygous (n=26) and homozygous group (n=3). Myocardial velocities (by pulsed and color tissue Doppler imaging) measured in the basal and mildventricular segment of the interventricular septal wall (IVS), left ventricular free wall (LVW), left ventricular anterior wall (LVAW), left ventricular posterior wall (LVPW) and radial segment of LVW, was compared among different groups. A decreased longitudinal Em velocities (pulsed tissue Doppler) at the mildventricular segment of LVW was observed in HCM cats compared with suspects and normal cats. A decreased longitudinal Em/Am (color tissue Doppler) at the basal segment of IVS was observed in HCM cats compared with suspects and normal cats. A significant increased longitudinal E/Em (color tissue Doppler) at the basal segment of IVS was observed in HCM cats compared with suspects and normal cats. And a significant decreased longitudinal Sm (color tissue Doppler) at the basal segment of the LVW was observed in heterozygous cats compared with negative cats, both without hypertrophy. There was a positive correlation between summated early and late diastolic velocities (Em/Am) and heart rate; and a positive correlation between Sm and Em velocities and heart rate, both in pulsed and in color TDI. TDI analyses are a new, valuable and reproducible method in cats that alone is not able to identify cats with mutation before myocardial hypertrophy. Despite high expectations regarding the use of TDI for early identification of individuals with HCM, there is still need for larger studies with greater numbers of individuals.

Abstract in Portuguese:

RESUMO.- Pellegrino A., Daniel A.G.T., Pereira G.G., Júnior F.F.L., Itikawa P.H. & Larsson M.H.M.A. 2014. [Assessment of diastolic function by pulsed and color tissue Doppler echocardiography in Maine Coon cats tested for MyBPC-A31P mutation.] Avaliação da função diastólica por meio de Doppler tecidual pulsado e colorido em gatos da raça Maine Coon geneticamente testados para a mutação no gene MyBPC-A31P. Pesquisa Veterinária Brasileira 34(3):290-300. Departamento de Clínica Médica, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Prof. Dr. Orlando Marques de Paiva 87, São Paulo, SP, 05508-270, Brazil. E-mail: arinepel@yahoo.com.br A cardiomiopatia hipertrófica (CMH) é a principal cardiopatia dos felinos e é caracterizada por hipertrofia miocárdica concêntrica, sem dilatação ventricular. Disfunções miocárdicas ocorrem em gatos com CMH, mas pouco se conhece a respeito destas alterações nos estágios iniciais da afecção. Em gatos da raça Maine Coon, a mutação no gene MyBPC-A31P está relacionada com a CMH de origem familial, porém, a correlação exata entre o genótipo e o fenótipo ainda é inconclusiva. A ecocardiografia tecidual é uma modalidade não invasiva que permite avaliação da função miocárdica e é mais sensível que a ecocardiografia convencional. Para avaliar as funções sistólica e diastólica, antes ou após a ocorrência de hipertrofia ventricular, gatos da raça Maine Coon (n=57), geneticamente testados para a mutação, foram avaliados por meio de ecocardiografias convencional e tecidual (nas modalidades Doppler tecidual pulsado e Doppler tecidual colorido). Posteriormente, foram fenotipicamente classificados em: normais (n=45), suspeitos (n=7) e acometidos pela CMH (n=5); e genotipicamente classificados em: negativos (n=28), heterozigotos (n=26) e homozigotos para a mutação (n=3). Valores de velocidades miocárdicas (Doppler tecidual pulsado e colorido) medidos na região basal e média do septo interventricular (SIV), da parede livre do ventrículo esquerdo (PVE), da parede anterior do ventrículo esquerdo (PAVE), da parede posterior do ventrículo esquerdo (PPVE) e do segmento radial da PVE, foram comparados nos diferentes grupos. Observou-se que as velocidades longitudinais Em (Doppler tecidual pulsado) na região média da PVE foram menores nos gatos com CMH quando comparados com suspeitos e normais. Os valores de Em/Am (Doppler tecidual colorido), na região basal do SIV, foram inferiores nos gatos com CMH quando comparados com suspeitos e normais. A relação E/Em (Doppler tecidual colorido), na região basal do SIV, foi maior nos gatos com CMH em relação aos suspeitos e normais, enquanto que os valores de Sm (Doppler tecidual colorido), em região basal da PVE, foram menores nos gatos heterozigotos quando comparados com os negativos, ambos sem hipertrofia ventricular. Observou-se correlação positiva entre a ocorrência de fusão das ondas Em e Am e a frequência cardíaca, assim como correlação positiva entre valores de Sm e Em e a frequência cardíaca (Doppler tecidual pulsado e colorido). A ecocardiografia tecidual é uma nova modalidade ecocardiográfica reprodutível em gatos que, isoladamente, não permite diferenciar gatos portadores da mutação antes do desenvolvimento de hipertrofia ventricular. Apresenta utilidade como auxílio no diagnóstico em fases iniciais, mas, apesar da expectativa para a identificação precoce de indivíduos portadores da CMH, ainda há necessidade de estudos mais extensos e com maior número de indivíduos.


#5 - Evaluation of aortic and pulmonary valves flow with pulsed-wave Doppler echocardiography in healthy dogs, 30(7):586-592

Abstract in English:

ABSTRACT.- Petrus L.C., Oliveira V.M.C., Pereira G.G. & Larsson M.H.M.A. 2010. [Evaluation of aortic and pulmonary valves flow with pulsed-wave Doppler echocardiography in healthy dogs.] Avaliação dos fluxos das valvas aórtica e pulmonar com ecocardiografia Doppler pulsátil em cães clinicamente sadios. Pesquisa Veterinária Brasileira 30(7):586-592. Departamento de Clínica Médica, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Professor Dr. Orlando Marques de Paiva 87, São Paulo, SP 05508-270, Brazil. E-mail: lilipetrus@hotmail.com This study evaluated aortic (AO) and pulmonary (Pul) valves flow with pulsed-wave Doppler by qualitative (presence of valvar insufficiency and characteristic of flow profile) and quantitative analysis, and the following echocardiographic parameters were obtained: peak (PV) and mean (MV) velocities, velocity-time integral (VTI), acceleration (AT) and ejection (ET) time. Thirty dogs were studied, and to be considered normal, physical, laboratory, electrocardiographic, echocardiographic (uni and bidimensional mode) exams, thoracic radiography, and measurement of the blood pressure were accomplished, and the following echocardiographic parameters were obtained: AO PV= 1.22±19.38m/s; AO MV= 0.72±0.08m/s; AO VTI= 0.14±0.02m; AO AT= 38.80±11.29ms; AO ET= 197.90±24.77ms; Pul PV= 0.95±0.18m/s; Pul MV= 0.63±0.10m/s; Pul VTI= 0.13±0.02m; Pul AT= 70.97±18.87ms; Pul ET= 203.70±28.98ms. Heart rate presented negative correlation with AO VTI, AO ET, Pul VTI, Pul AT, Pul ET, and the variable weight had positive correlation with AO VTI, AO AT, AO ET, Pul VTI, Pul ET, differently from the gender, that had no influence on the evaluated parameters. The comparison of aortic and pulmonary valves flow demonstrated AO PV and AO MV higher than Pul PV and Pul MV, respectively, AO VTI higher than Pul VTI, and Pul AT higher than AO AT.

Abstract in Portuguese:

RESUMO.- Petrus L.C., Oliveira V.M.C., Pereira G.G. & Larsson M.H.M.A. 2010. [Evaluation of aortic and pulmonary valves flow with pulsed-wave Doppler echocardiography in healthy dogs.] Avaliação dos fluxos das valvas aórtica e pulmonar com ecocardiografia Doppler pulsátil em cães clinicamente sadios. Pesquisa Veterinária Brasileira 30(7):586-592. Departamento de Clínica Médica, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Professor Dr. Orlando Marques de Paiva 87, São Paulo, SP 05508-270, Brazil. E-mail: lilipetrus@hotmail.com Avaliaram-se com Doppler pulsátil os fluxos das valvas aórtica (AO) e pulmonar (Pul) por meio de análise qualitativa (presença de regurgitações valvares e características do espectro avaliado) e quantitativa, com obtenção de parâmetros ecocardiográficos como velocidades máxima (V. Max.) e média (V. Me.), integral de velocidade (VTI), tempo de aceleração (TA) e ejeção (TE), de 30 cães considerados clinicamente sadios por meio de exames físico, laboratoriais, eletrocardiográfico, ecocardiográfico (modos uni e bidimensional), radiográfico de tórax e mensuração da pressão arterial sistêmica. Obtiveram-se os seguintes resultados para os referidos parâmetros: V.max. AO= 1,22±19,38m/s; V. Me. AO= 0,72±0,08m/s; VTI AO= 0,14±0,02m; TA AO= 38,80±11,29ms; TE AO= 197,90±24,77ms; V. Max. Pul= 0,95±0,18m/s; V. Me. Pul= 0,63±0,10m/s; VTI Pul= 0,13±0,02m; TA Pul= 70,97±18,87ms; TE Pul= 203,70± 28,98ms. Em apenas três animais observou-se regurgitação pulmonar. Alguns parâmetros apresentaram correlação negativa com a variável freqüência cardíaca (VTI AO, TE AO, VTI Pul, TA Pul, TE Pul); outros correlação positiva com a variável peso (VTI AO, TA AO, TE AO, VTI Pul, TE Pul,) e não se observou influência da variável sexo na maioria dos parâmetros avaliados. Na comparação entre os dois fluxos, observaram-se V. Max. AO e V. Me. AO maiores que V. Max. Pul. e V. Me. Pul., respectivamente, VTI AO maior que VTI Pul, e TA AO menor que TA Pul.


#6 - Evaluation of left ventricular diastolic echocardiographic parameters in healthy dogs by pulsed-wave Doppler, p.291-294

Abstract in English:

ABSTRACT.- Pereira G.G., Petrus L.C., Santos A.L.F., Yamaki F.L. & Larsson M.H.M.A. 2009. Evaluation of left ventricular diastolic echocardiographic parameters in healthy dogs by pulsed-wave Doppler. Pesquisa Veterinária Brasileira 29(4):291-294. Departamento de Clínica Médica, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Prof. Orlando Marques de Paiva 87, São Paulo, SP 05508-900, Brazil. E-mail: ggpereira2002@yahoo.com.br Left ventricular diastolic dysfunction plays an important role on heart failure progression. In order to obtain additional reference values of left ventricular diastolic parameters and investigate influence of common variables, peak E wave (peak E), peak A wave (peak A), E/A ratio (E/A), E wave deceleration time (EDT) and isovolumic relaxation time (IRVT) were studied in 40 clinically healthy dogs, by pulsed wave Doppler. The following values were obtained: peak E = 0.747 ± 0.117 m/s, peak A = 0.487 ± 0.062 m/s, E/A = 1.533 ± 0.198, EDT = 88.7 ± 9.2 ms and IRVT = 0.080 ± 0.009 s. Some parameters were influenced by heart rate (peak E, peak A and IRVT), by age (peak A and E/A) and by body weight (TRIV). Gender influence was absent. Values obtained can be used as reference for canine specimens but its interpretation should consider on the influence of related variables.

Abstract in Portuguese:

ABSTRACT.- Pereira G.G., Petrus L.C., Santos A.L.F., Yamaki F.L. & Larsson M.H.M.A. 2009. Evaluation of left ventricular diastolic echocardiographic parameters in healthy dogs by pulsed-wave Doppler. Pesquisa Veterinária Brasileira 29(4):291-294. Departamento de Clínica Médica, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Prof. Orlando Marques de Paiva 87, São Paulo, SP 05508-900, Brazil. E-mail: ggpereira2002@yahoo.com.br Left ventricular diastolic dysfunction plays an important role on heart failure progression. In order to obtain additional reference values of left ventricular diastolic parameters and investigate influence of common variables, peak E wave (peak E), peak A wave (peak A), E/A ratio (E/A), E wave deceleration time (EDT) and isovolumic relaxation time (IRVT) were studied in 40 clinically healthy dogs, by pulsed wave Doppler. The following values were obtained: peak E = 0.747 ± 0.117 m/s, peak A = 0.487 ± 0.062 m/s, E/A = 1.533 ± 0.198, EDT = 88.7 ± 9.2 ms and IRVT = 0.080 ± 0.009 s. Some parameters were influenced by heart rate (peak E, peak A and IRVT), by age (peak A and E/A) and by body weight (TRIV). Gender influence was absent. Values obtained can be used as reference for canine specimens but its interpretation should consider on the influence of related variables.


Colégio Brasileiro de Patologia Animal SciELO Brasil CAPES CNPQ UNB UFRRJ CFMV